Favorites Store Locator Contact My Account
  • News & events

Delta Plus Knowledge

We help you to develop your skills through training, our tutorials and our centres of expertise. Easily find all the product and regulatory information relating to our ranges thanks to our download centre.

Our mission

For more than 45 years, Delta Plus designs, standardises, manufactures, and distributes globally a full set of solutions in personal and collective protective equipment (PPE) to protect professional at work.

Family history

Our history

#

Standards and directives

We operate in a regulated global market in many countries. Thus, we must manage requirements that may vary greatly between countries or regions.
The common goal of our product managers and services is to offer reliable, sustainable, high-performance products in compliance with the regulations and/or standards of each territory where they are used.
#
#

Standards and certifications

All you need to know about PPE standards

Filter
Standards

GS-ET 29

Requirements, performances, test methods relating to face shields providing protection against electric arcing.

EN 172

Specification of level numbers and requirements relating to the transmittance of filters for protection against solar radiation, industrial use.

ANSI (US American National Standards Institute) S3.19 - 1974

This standard specifi es the test method for determining the level of noise attenuation (NRR Noise Reduction Rating) of the hearing protection, as recommended by the EPA (U.S. Environmental Protection Agency).

ANSI/ISEA Z89.1: American standard for head protection in industry

MANDATORY

Type 1: The impact force transmitted to the cap must not exceed 4,450 N when a 3.6 kg (8 lb) impact is dropped at a speed of 5.5 m/s (metres per second).
Penetration: A 1 kg penetrator must not come into contact with the false head at a speed of 7.0 m/s.
Flammability: the helmet must not burn with the emission of a fl ame for more than 5 seconds after the fl ame has been withdrawn
Electrical resistance: proof test at 20,000 volts for class E or 10,000 volts for class G. Class C off ers no protection against electrical hazards.
Type 2: In addition to the requirements of type 1, type 2 head protection must also satisfy:
Energy attenuation: the acceleration must not exceed 150 g in the event of a fall onto the cap and sideways using a 5 kg dummy head at 3.5 m/s.
Lateral penetration: At the front, rear and sides, a 1 kg penetrator must not come into contact with the headform at a speed of 5.0 m/s.

OPTIONAL

ANSI/ISEA Z89.1 4 options: low temperature (LT), high temperature (HT), reverse wear position and high visibility.